618 – Oxygen
About this valve
The Müller type 618 industrial VIPR sets new standards with its new innovative design. It is equipped with a two stage regulating unit including safety valve and RPV function. The regulating unit has a patented balanced system allowing you to change the fl ow settings by applying a constant torque. Pressure gauge and flow meter are incorporated into the main valve body for better protection.
For easy maintenance of the regulating unit, the main valve can be shut offand the complete unit can be replaced without further disassembly.
The valve is manufactured on state of the art manufacturing equipment, and the quality is monitored throughout the entire process. It is assembled on a fully automated assembly line using Helium as media for accurate leak testing. The valve is subjected to a 100% functional test on the assembly line with complete records of all test results, ensuring full data traceability. When the valve has passed all tests on the assembly line, it is allocated a unique serial number relating to the recorded test data, giving you a world class industrial VIPR!
Product Details | |
---|---|
MGE type | 618, Oxygen |
Inlet | 25E, other on request |
Outlet | G 3/8″, other on request |
Burst Disc | On request |
RPV | Yes |
Inlet pressure indicator | 0-360 bar |
Outlet pressure gauge | 0-10 bar |
1. Stage regulation system | From inlet pressure to max. 50 bar |
2. Stage regulation system | Adjustable from 0 to 6 bar |
Handwheel | Plastic, black |
Logo plug | Neutral or with logo |
Tape | On request |
Approved | PI 0589 (ISO22435) |
Leak valve | Yes |
Surface treatment | On request |
Do you have questions regarding 618 – Oxygen?
Please fill out the form and we will get back to you.